User's Manual
Using the Storage Management Service 159
omreport Controller Status
omreport Global Information (Smart Thermal Shutdown Status)
omreport Battery Status
Table 9-4. omreport Controller Commands
Required Command Levels (1, 2, 3) Optional name=value pairs Use
omreport storage controller Displays property information for
all controllers attached to the
system.
controller=id
where id is the controller number.
For example: controller=0
Displays the specified controller
and all attached components such
as enclosures, virtual disks, array
disks, and so on.
Table 9-5. omreport Global Information Commands
Required Command Levels (1, 2, 3) Optional name=value pairs Use
omreport storage globalinfo Displays whether smart thermal
shutdown is enabled or disabled. See
the "omconfig Global Enable Smart
Thermal Shutdown" command for
more information.
Table 9-6. omreport Battery Commands
Required Command Levels (1, 2, 3) Optional name=value pairs Use
omreport storage battery Displays all batteries present on all
controllers on the system. (Some
controllers do not have batteries).
controller=id
where id is the controller
number. For example:
controller=0
Displays the battery on the specified
controller.