User's Manual

omconfig: Managing Components Using the Instrumentation Service 119
omconfig system thrmshutdown
Use the omconfig system thrmshutdown command to configure a thermal shutdown action. A thermal
shutdown can be configured to occur when a temperature probe detects a temperature probe warning or
failure event.
Table 5-29 shows the valid parameters for the command.
Example Thermal Shutdown Commands
To trigger a thermal shutdown when a temperature probe detects a failure event, type:
omconfig system thrmshutdown severity=failure
To disable thermal shutdown so that an administrator has to initiate an omconfig system shutdown,
type:
omconfig system thrmshutdown severity=disabled
Table 5-29. Thermal Shutdown Parameters
name=value pair Description
severity=disabled | warning | failure disabled: Disable thermal shutdown. An administrator
must intervene.
warning: Perform a shutdown when a temperature warning
event is detected. A warning event occurs when any
temperature probe inside a chassis reads a temperature (in
degrees Celsius) which exceeds the maximum temperature
warning threshold.
failure: Perform a shutdown when a temperature failure
event is detected.
A failure event occurs when any temperature probe inside a
chassis reads a temperature (in degrees Celsius) that
exceeds the maximum temperature failure threshold.