omconfig: Managing Components Using the Instrumentation Service 111
Example Set Alert Action Commands
The examples below are valid example commands. For each successful command issued, the following
message appears:
Alert action(s) configured successfully.
Example Current Probe Actions
To disable system console alert if a current probe detects a warning event, type:
omconfig system alertaction event=currentwarn alert=false
To enable broadcast messages if a current probe detects a failure event, type:
omconfig system alertaction event=currentfail broadcast=true
Example Fan Probe Actions
To generate alerts when a fan probe detects a failure value, type:
omconfig system alertaction event=fanfail alert=true
Example Chassis Intrusion Actions
To clear all alert actions for chassis intrusion, type:
omconfig system alertaction event=intrusion clearall=true
Commands for Clearing Logs
NOTE: For more information about alert messages, see the Dell OpenManageâ„¢ Server Administrator Messages
Reference Guide.
You can use the omconfig system command to clear three logs: the alert log, the command log, and the
hardware, or ESM, log.
To clear the contents of the alert log, type:
omconfig system alertlog action=clear
NOTE: Entering an invalid RAC user name may prevent the command log from displaying. Clearing the command
log resolves this condition.
event=voltwarn Sets actions when a voltage probe detects a warning value.
event=voltfail Sets actions when a voltage probe detects a failure value.
event=watchdogasr Sets actions that Server Administrator performs on the next system startup after a
watchdog Automatic System Recovery (ASR) is performed for a hung
operating system.
Table 5-20. Events for Which You Can Set Alert Actions (continued)
Event Name Description