User's Manual
102 omconfig: Managing Components Using the Instrumentation Service
config=user id=number enable=true | false id=number: ID number of the user
being configured.
enable=true: Enables user.
enable=false: Disables user.
id=number enableserialoverlan=true
| false
id=number: ID number of the user being
configured.
enableserialoverlan=true: Enables serial
over LAN.
enableserialoverlan=false: Disables serial
over LAN.
NOTE: The option enableserialoverlan is
supported only on PowerEdge 1900, 1950, 1955,
2900, and 2950 systems.
id=number name=text number: ID number of the user
being configured.
name=text: Name of the user.
id=number newpw=text
confirmnewpw=text
number: ID number of the user
being configured.
newpw=text: New password of the user.
confirmnewpw=text: Confirm new password
of the user.
id=number serialaccesslevel=
administrator | operator | user | none
id=number: ID number of the user
being configured.
serialaccesslevel=administrator: User with an
ID has access privileges of an Administrator
for the Serial Port channel.
serialaccesslevel=operator: User with an ID
has access privileges of an Operator for the
serial port channel.
serialaccesslevel=user: User with an ID has
access privileges of a User for the
serial port Channel.
serialaccesslevel=none: User with an ID does
not have access privileges for the
serial port channel.
Table 5-12. omconfig chassis remoteaccess (continued)
name=value pair 1
config=
name=value pair 2 Description