Messages Reference Guide
94 Storage Management Message Reference
2282 Hot spare SMART
polling failed.
Critical /
Failure /
Error
Cause: The controller firmware attempted a
SMART polling on the hot spare but was
unable to complete it. The controller has lost
communication with the hot spare.
Action: Check the health of the disk assigned
as a hot spare. You may need to replace the
disk and reassign the hot spare. Make sure the
cables are attached securely. See the Cables
Attached Correctly section in the
Dell OpenManage Server Administrator
Storage Management User’s Guide for more
information on checking the cables.
904 None
2283 A redundant path is
broken.
Warni ng /
Non-critical
Cause: The controller has two connectors
that are connected to the same enclosure.
The communication path on one connector
has lost connection with the enclosure. The
communication path on the other connector
is reporting this loss.
Action: Make sure the cables are attached
securely. Make sure both EMMs are healthy.
903 None
2284 A redundant path has
been restored.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
901 None
2285 A disk media error
was corrected during
recovery.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
901 None
2286 A Learn cycle start is
pending while the
battery charges.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
1151 None
2287 The Patrol Read is
paused.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
751 None
2288 The patrol read has
resumed.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
751 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number