Messages Reference Guide
Storage Management Message Reference 93
2278 The controller battery
charge level is below
a normal threshold.
Ok / Normal Cause: The battery is discharging. A battery
discharge is a normal activity during the
battery Learn cycle. Before completing, the
battery Learn cycle recharges the battery. You
should receive alert 2179 when the recharge
occurs.
Action: Check if the battery Learn cycle is in
progress. Alert 2176 indicates that the battery
Learn cycle has initiated. The battery also
displays the Learn state while the Learn cycle
is in progress. If a Learn cycle is not in
progress, replace the battery pack.
1154 None
2279 The controller battery
charge level is above a
normal threshold.
Ok / Normal Cause: This alert is provided for informational
purposes. This alert indicates that the battery
is recharging during the battery Learn cycle.
Action: None
1151 None
2280 A disk media error has
been corrected.
Ok / Normal Cause: A disk media error was detected
while the controller was completing a
background task. A bad disk block was
identified. The disk block has been
remapped.
Action: Consider replacing the disk. If you
receive this alert frequently, be sure to replace
the disk. You should also routinely back up
your data.
1201 None
2281 Virtual disk has
inconsistent data.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
1201 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number