Messages Reference Guide
92 Storage Management Message Reference
2272 Patrol Read found an
uncorrectable media
error.
Critical /
Failure /
Error
Cause: The Patrol Read task has faced an
error that cannot be corrected. There may be
a bad disk block that cannot be remapped.
Action: Replace the array disk to avoid future
data loss.
903 None
2273 Bad media. Critical /
Failure /
Error
Cause: A source (array) disk in a redundant
virtual disk has a bad disk block. The algorithm
that maintains redundant data has created a
similar bad block on the target redundant
disk to maintain consistency in disk block
addressing. Data has been lost.
Action: Restore from backup.
904 None
2274 The array disk rebuild
has resumed.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
901 None
2276 The dedicated hot
spare is too small.
Warni ng /
Non-critical
Cause: The dedicated hot spare is not large
enough to protect all virtual disks that reside
on the disk group.
Action: Assign a larger disk as the dedicated
hot spare.
903 None
2277 The global hot spare
is too small.
Warni ng /
Non-critical
Cause: The global hot spare is not large enough
to protect all virtual disks that reside on the
controller.
Action: Assign a larger disk as the global
hot spare.
903 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number