Messages Reference Guide
90 Storage Management Message Reference
2264 A device is missing. Warning /
Non-critical
Cause: The controller cannot communicate
with a device. The device may be removed.
There may also be a bad or loose cable.
Action: Check if the device is in and not
removed. If it is in, check the cables. You
should also check the connection to the
controller battery and the battery health.
A battery with a weak or depleted charge
may cause this alert.
753, 803,
853, 903,
953, 1003,
1053, 1103,
1153, 1203
None
2265 A device is in an
unknown state.
Warni ng /
Non-critical
Cause: The controller cannot communicate
with a device. The state of the device cannot
be determined. There may be a bad or loose
cable. The system may also be experiencing
problems with the application programming
interface (API). There could also be a
problem with the driver or firmware.
Action: Check the cables. Check if the
controller has a supported version of the
driver and firmware. You can download the
most current version of the driver and
firmware from support.dell.com. Rebooting
the system may also resolve this problem.
753, 803,
853, 903,
953, 1003,
1053, 1103,
1153, 1203
None
2266 Controller log file
entry: %1
NOTE: %1 is a
substitution variable
that will appear in the
alert description for
specific details about
the alert.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
751 None
2267 The controller
reconstruct rate has
changed.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
751 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number