Messages Reference Guide

Storage Management Message Reference 83
2181 The controller battery
Learn cycle will start
in % hours.
NOTE: The % is a
variable that will be
replaced with the
number of hours
before which the
Learn cycle will start.
You can set the
duration to start the
Learn cycle.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
1151 None
2182 An invalid SAS
configuration has
been detected.
Critical /
Failure /
Error
Cause: The controller and attached
enclosures are not cabled correctly.
Action: See the hardware documentation for
information on correct cabling
configurations.
754 None
2186 The controller cache
has been discarded.
Warni ng /
Non-critical
Cause: The controller has flushed the cache
and any data in the cache has been lost. This
may happen if the system has memory or
battery problems that cause the controller to
distrust the cache. Although user data may have
been lost, this alert does not always indicate
that relevant or user data has been lost.
Action: Verify that the battery and memory
are functioning properly.
753 None
2187 Single-bit ECC error
limit exceeded.
Warni ng /
Non-critical
Cause: The system memory is
malfunctioning.
Action: Replace the battery pack.
753 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number