Messages Reference Guide

80 Storage Management Message Reference
2167 The current kernel
version and the non-
RAID SCSI driver
version are older than
the minimum
required levels.
See the Readme file
for a list of validated
kernel and driver
versions.
Warni ng /
Non-critical
Cause: The version of the kernel and the
driver do not meet the minimum requirements.
Storage Management may not be able to
display the storage or perform storage
management functions until you have
updated the system to meet the minimum
requirements.
Action: See the Readme file for kernel and
driver requirements. Update the system to
meet the minimum requirements and then
reinstall Storage Management.
103 None
2168 The non-RAID SCSI
driver version is older
than the minimum
required level.
See the Readme file
for the validated
driver version.
Warni ng /
Non-critical
Cause: The version of the driver does not
meet the minimum requirements. Storage
Management may not be able to display the
storage or perform storage management
functions until you have updated the system
to meet the minimum requirements.
Action: See the Readme file for the driver
requirements. Update the system to meet the
minimum requirements and then reinstall
Storage Management.
103 None
2169 The controller battery
needs to be replaced.
Critical /
Failure /
Error
Cause: The controller battery cannot recharge.
The battery may be old or it may have been
already recharged the maximum number of
times. In addition, the battery charger may
not be working.
Action: Replace the battery pack.
1154 None
2170 The controller battery
charge level is normal.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
1151 None