Messages Reference Guide
74 Storage Management Message Reference
2132 Driver version
mismatch
Warni ng /
Non-critical
Cause: The controller driver is not a
supported version.
Action: Install a supported version of the driver.
If you do not have a supported driver version
available, it can be downloaded from the
Dell support site at support.dell.com. If you
do not have a supported version of the driver
available, check with your support provider
for information on how to obtain the most
current driver.
753 None
2135 Array Manager is
installed on the
system
Warni ng /
Non-critical
Cause: Storage Management has been installed
on a system that has an Array Manager
installation.
Action: Installing Storage Management and
Array Manager on the same system is not a
supported configuration. Uninstall either
Storage Management or Array Manager.
103 None
2136 Virtual disk
initialization
Ok / Normal Cause: Virtual disk initialization is in progress.
This alert is provided for informational
purposes.
Action: None
1201 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number