Messages Reference Guide

Storage Management Message Reference 69
2110 SMART warning
degraded
Warni ng /
Non-critical
Cause: A disk is degraded and has received a
SMART alert (predictive failure). The disk is
likely to fail in the near future.
Action: Replace the disk that has received the
SMART alert. If the array disk is a member of
a non-redundant virtual disk, then back up
the data before replacing the disk. Removing
an array disk that is included in a non-
redundant virtual disk will cause the virtual
disk to fail and may cause data loss.
903 589
2111 Failure prediction
threshold exceeded
due to test - No
action needed
Warni ng /
Non-critical
Cause: A disk has received a SMART alert
(predictive failure) due to test conditions.
Action: None
903 590
2112 Enclosure was shut
down
Critical /
Failure /
Error
Cause: The array disk enclosure is either
hotter or cooler than the maximum or
minimum allowable temperature range.
Action: Check for factors that may cause
overheating or excessive cooling. For example,
verify that the enclosure fan is working. You
should also check the thermostat settings and
examine whether the enclosure is located
near a heat source. Make sure the enclosure
has enough ventilation and that the room
temperature is not too hot or too cold. See
the enclosure documentation for more
diagnostic information.
854 602
2114 A consistency check
on a virtual disk has
been paused
(suspended)
Ok / Normal Cause: The check consistency operation on a
virtual disk was paused by a user.
Action: To resume the check consistency
operation, right-click the virtual disk in the
Storage Management tree view and select
Resume Check Consistency.
1201 604