Messages Reference Guide

Storage Management Message Reference 61
2059 Virtual disk format
started
Ok / Normal Cause: This alert is provided for informational
purposes.
Action: None
1201 521
2061 Virtual disk
initialization started
Ok / Normal Cause: This alert is provided for informational
purposes.
Action: None
1201 523
2063 Virtual disk
reconfiguration
started
Ok / Normal Cause: This alert is provided for informational
purposes.
Action: None
1201 525
2064 Virtual disk rebuild
started
Ok / Normal Cause: This alert is provided for informational
purposes.
Action: None
1201 526
2065 Array disk rebuild
started
Ok / Normal Cause: This alert is provided for informational
purposes.
Action: None
901 527
2067 Virtual disk check
consistency cancelled
Ok / Normal Cause: The check consistency operation
cancelled because a physical disk in the array
has failed or because a user cancelled the
check consistency operation.
Action: If the physical disk failed, then replace
the physical disk. You can identify which disk
failed by locating the disk that has a red “X”
for its status. Perform a rescan after replacing
the disk. When performing a consistency
check, be aware that the consistency check
can take a long time. The time it takes
depends on the size of the physical disk or
the virtual disk.
1201 529
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number