Messages Reference Guide
Storage Management Message Reference 59
2050 Array disk offline Warning /
Non-critical
Cause: A physical disk in the array is offline.
A disk can be made offline during a Prepare
to Remove operation or because a user
manually put the disk offline.
Action:
Perform a rescan. You can also select
the offline disk and perform a Make Online
operation.
903 502
2051 Array disk degraded Warning /
Non-critical
Cause: An array disk has reported an error
condition and may be degraded. The array
disk may have reported the error condition in
response to a consistency check or other
operation.
Action: Replace the degraded array disk. You
can identify which disk is degraded by locating
the disk that has a red "X" for its status.
Perform a rescan after replacing the disk.
903 503
2052 Array disk inserted Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
901 504
2053 Virtual disk created Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
1201 505
2054 Virtual disk deleted Warning /
Non-critical
Cause: A virtual disk has been deleted.
"Performing a Reset Configuration" may
detect that a virtual disk has been deleted
and generate this alert.
Action: None
1203 506
2055 Virtual disk
configuration
changed
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
1201 507
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number