Messages Reference Guide

14 Event Message Reference
1005 SMBIOS data is absent Warning The system does not contain the
required systems management BIOS
version 2.2 or higher, or the BIOS is
corrupted.
1006 Automatic System Recovery
(ASR) action was performed
Action performed was:
<Action>
Date and time of action:
<Date
and time>
Error This message is generated when an
automatic system recovery action is
performed due to a hung operating
system. The action performed and the
time of action are provided.
1007 User initiated host system
control action
Action requested was:
<Action>
Information User requested a host system control
action to reboot, power off, or power
cycle the system. Alternatively the user
had indicated protective measures to be
initiated in the event of a thermal
shutdown.
1008 Systems Management Data
Manager Started
Information Systems Management Data Manager
services were started.
1009 Systems Management Data
Manager Stopped
Information Systems Management Data Manager
services were stopped.
1011 RCI table is corrupt Warning This message is generated when the
BIOS Remote Configuration Interface
(RCI) table is corrupted or cannot be
read by the systems management
software.
1012 IPMI Status
Interface: <
the IPMI interface
being used
>, <
additional
information if available and
applicable
>
Information This message is generated to indicate
the Intelligent Platform Management
Interface (IPMI)) status of the system.
Additional information, when available,
includes Baseboard Management
Controller (BMC) not present, BMC
not responding, System Event Log (SEL)
not present, and SEL Data Record (SDR)
not present.
Table 2-1. Miscellaneous Messages (continued)
Event ID Description Severity Cause