Messages Reference Guide
104 Storage Management Message Reference
2334 Controller event
log: %1
NOTE: %1 is a
substitution variable
that will appear in the
alert description for
specific details about
the alert.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
751 None
2335 Controller event
log: %1
NOTE: %1 is a
substitution variable
that will appear in the
alert description for
specific details about
the alert.
Warni ng /
Non-critical
Cause: The text for this alert is generated by
the controller and can vary depending on the
situation. This text is from events in the
controller event log that were generated while
Storage Management was not running.
Action: If there is a problem, review the
controller event log and the Server
Administrator Alert Log for significant events
or alerts that may assist in diagnosing the
problem. Check the health of the storage
components. See the hardware
documentation for more information.
753 None
2336 Controller event
log: %1
NOTE: %1 is a
substitution variable
that will appear in the
alert description for
specific details about
the alert.
Critical /
Failure /
Error
Cause: The text for this alert is generated by
the controller and can vary depending on the
situation. This text is from events in the
controller event log that were generated while
Storage Management was not running.
Action: See the hardware documentation for
more information.
754 None
2337 The controller is unable
to recover cached
data from the battery
backup unit (BBU).
Critical /
Failure /
Error
Cause: The controller was unable to recover
data from the cache.
Action: Check if the battery is charged and in
good health. When the battery charge is
unacceptably low, it cannot maintain cached
data. Check if the battery has reached its
recharge limit. The battery may need to be
recharged or replaced.
1154 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number