Messages Reference Guide

102 Storage Management Message Reference
2324 The AC power supply
cable has been
removed.
Critical /
Failure /
Error
Cause: The power cable may be pulled out
or removed. The power cable may also have
overheated and become warped and
nonfunctional.
Action: Replace the power cable.
1004 None
2325 The power supply
cable has been
inserted.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
1001 None
2326 A foreign
configuration has
been detected.
Ok / Normal Cause: This alert is provided for informational
purposes. The controller has array disks that
were moved from another controller. These
array disks contain virtual disks that were
created on the other controller. See the Import
Foreign Configuration and Clear Foreign
Configuration section in the Dell OpenManage
Server Administrator Storage Management
User’s Guide for more information.
Action: None
751 None
2327 The NVRAM has
corrupted data. The
controller is
reinitializing the
NVRAM.
Warni ng /
Non-critical
Cause: The NVRAM has corrupted data.
This may occur after a power surge, a battery
failure, or for other reasons. The controller is
reinitializing the NVRAM.
Action: None. The controller is taking the
required corrective action. If this alert is
generated often (such as during each reboot),
replace the controller.
753 None
2328 The NVRAM has
corrupt data.
Warni ng /
Non-critical
Cause: The NVRAM has corrupt data. The
controller is unable to correct the situation.
Action: Replace the controller.
753 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number