Messages Reference Guide
100 Storage Management Message Reference
2314 The initialization
sequence of SAS
components failed
during system
startup. SAS
management and
monitoring is not
possible.
Critical /
Failure /
Error
Cause: Storage Management is unable to
monitor or manage SAS devices.
Action: Reboot the system. If problem
persists, make sure you have supported
versions of the drivers and firmware. Also, you
may need to reinstall Storage Management or
Server Administrator because of some
missing installation components.
104 None
2315 Diagnostic message %1
NOTE: %1 is a
substitution variable
that will appear in the
alert description for
specific details about
the alert.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
751 None
2316 Diagnostic message %1
NOTE: %1 is a
substitution variable
that will appear in the
alert description for
specific details about
the alert.
Critical /
Failure /
Error
Cause: A diagnostics test failed. The text for
this alert is generated by the utility that ran
the diagnostics.
Action: See the documentation for the utility
that ran the diagnostics for more
information.
754 None
2317 BGI terminated due
to loss of ownership
in a cluster
configuration.
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
1201 None
2318 Problems with the
battery or the battery
charger have been
detected. The battery
health is poor.
Critical /
Failure /
Error
Cause: The battery or the battery charger is
not functioning properly.
Action: Replace the battery pack.
1154 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number