Users Guide

Working With the Baseboard Management Controller (BMC) 85
Setting Platform Event Alert Destinations
You can also use the Platform Event Filters window to select a destination where an alert for a platform
event is to be sent. Depending on the number of destinations that are displayed, you can configure a
separate IP address for each destination address. A platform event alert will be sent to each destination
IP address that you configure.
1
Click
Configure Destinations
in the
Platform Event Filters
window.
The
Configure Destinations
window displays a number of destinations.
2
Click the number of the destination you want to configure.
NOTE: The number of destinations that you can configure on a given system may vary.
3
Click
Destination Number
to enter an individual IP address for that destination. This IP address is the
IP address to which the platform event alert will be sent.
4
Enter a value in the
Community String
field to act as a password to authenticate messages sent
between a management station and a managed system. The community string (also called the
community name) is sent in every packet between the management station and a managed system.
5
Click
Apply Changes
.
6
Click
Go Back to Platform Events Page
to go back to the
Platform Event Filters
window.
Configuring the BMC to use a Serial Over LAN (SOL) Connection
You can configure the BMC on a serial over LAN connection.
1
Click the
System
object.
2
Click the
Main System Chassis
object.
3
Click the
BMC
object.
4
Click the
Configuration
tab.
5
Click
Serial Over LAN
.
The
Serial Over LAN Configuration
window appears.
6
Configure the following details:
Enable Serial Over LAN
Baud Rate
Channel Privilege Limit
7
Clic
k Apply Changes.
8
Click
Advanced Settings
to further configure BMC.
9
In the
Serial Over LAN Configuration Advanced Settings window
, specify the following information:
Character Accumulate Interval
Character Send Threshold