omconfig: Managing Components Using the Instrumentation Service 91
omconfig chassis currents
Use the omconfig chassis currents command to set amperage probe warning thresholds. As with other
components, you can view both warning and failure threshold values, but you cannot set failure thresholds.
Your system's manufacturer sets the minimum and maximum failure thresholds.
NOTE: Settable thresholds vary from one system configuration to another.
NOTE: Systems that contain embedded systems management 3 (ESM3) capabilities do not allow you to set
warning threshold values to default values.
Valid Parameters for Current Warning Thresholds
Table 6-4 shows the valid parameters for setting current warning thresholds:
NOTE: The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of
status, readings, and thresholds set for all current probes present on your system. "Current probes are not present
in all systems". If you specify the index, Server Administrator displays a summary for a specific current probe.
config=user
(continued)
id=number lanaccesslevel=
administrator | operator | user| none
id=number: ID number of the user
being configured.
lanaccesslevel=administrator: User
with an ID has access privileges of an
Administrator for the LAN channel.
lanaccesslevel=operator: User with
an ID has access privileges of an
Operator for the LAN channel.
lanaccesslevel=user: User with an ID
has access privileges of a User for the
LAN channel.
lanaccesslevel=none: User with an ID
does not have access privileges for the
LAN channel.
Table 6-4. omconfig chassis currents
name=value pair Description
index=<n> Number of the probe or probe index (must be specified).
warnthresh=default Sets minimum and maximum warning thresholds to default.
minwarnthresh=<n> Minimum warning threshold (3 decimal places).
maxwarnthresh=<n> Maximum warning threshold (3 decimal places).
Table 6-3. omconfig chassis bmc (continued)
name=value pair 1
config=
name=value pair 2 Description