User's Manual
88 omconfig: Managing Components Using the Instrumentation Service
config=serial
(continued)
privilegelevel=administrator | operator
| user
administrator: Sets the maximum
privilege level that can be accepted on
a serial connection, to Administrator.
operator: Sets the maximum privilege
level that can be accepted on a serial
connection, to Operator.
user: Sets the maximum privilege
level that can be accepted on a serial
connection, to User.
enable=true | false true: Enables serial over LAN for
the BMC.
false: Disables serial over LAN for
the BMC.
baudrate=9600 | 19200 9600: Sets the volatile and nonvolatile
connection speed to 9600 bits per
second.
19200: Sets the volatile and
nonvolatile connection speed to
19200 bits per second.
privilegelevel=administrator | operator
| user
administrator: Sets the maximum
privilege level that can be accepted on
a serial over LAN channel, to
Administrator.
operator: Sets the maximum privilege
level that can be accepted on a serial
over LAN channel, to Operator.
user: Sets the maximum privilege
level that can be accepted on a serial
over LAN channel, to User.
config=settodefault Takes the default configuration
settings.
config=terminalmode deletecontrol=outputdel |
outputbkspspbksp
outputdel: BMC outputs a <del>
character when <bksp> or <del> is
received.
outputbkspspbksp: BMC outputs a
<bksp><sp><bksp> character
when <bksp> or <del> is received.
Table 6-3. omconfig chassis bmc (continued)
name=value pair 1
config=
name=value pair 2 Description