User's Manual

omconfig: Managing Components Using the Instrumentation Service 85
omconfig chassis bmc
Use the omconfig chassis bmc command to configure:
The BMC on a local area network (LAN)
The serial port for BMC
The BMC on a serial over LAN connection
Terminal settings for the serial port
Advanced settings for a serial over LAN connection
Information on a BMC user
NOTE: You have to enter the user ID to configure user information.
Ty p e :
omconfig chassis bmc
The output from the omconfig chassis bmc command lists each of the available configurations.
Table 6-3 shows the valid parameters:
Table 6-3. omconfig chassis bmc
name=value pair 1
config=
name=value pair 2 Description
config=advsol characcuminterval=number number: Sets the character
accumulate interval in 5 millisecond
intervals.
charsendthreshold=number number: Sets the number of
characters. BMC automatically sends
a serial over LAN data packet that
contains this number of characters as
soon as this number of characters
(or greater) has been accepted from
the baseboard serial controller into
the BMC.
config=nic enable=true | false true: Enables IPMI over LAN.
false: Disables IPMI over LAN.
gateway=Gateway gateway: Sets a gateway address if you
have selected static as the IP address
source for the BMC LAN interface.
IP address=IP ip: Sets the IP address if you have
selected static as the IP address source
for the BMC LAN interface.