70 omreport storage: Using the Storage Reports
omreport storage enclosureinfo
Use the omreport storage enclosureinfo enclosure=ID command (where ID is the ID number for the
enclosure) to view information about a single enclosure. For example, if the enclosure's ID is
"447244640512," enter the following command to see detailed information for that enclosure:
omreport storage enclosureinfo enclosure=47244640512
NOTE: You can find an enclosure ID by running the omreport storage enclosures command, which shows the
properties for all of the enclosures in the system.
The following information displays for the enclosure:
•Fans
Status — Status of the fan.
Name — Name of the fan.
State — Current state of the fan.
Speed — Speed at which the fan is running.
Temperature Probes
Status — Status of the temperature probes.
State — State of the temperature probes.
Reading — Actual temperature measured by a particular probe. Readings are always a snapshot of
a device's measurements at a point in time.
Minimum Warning Threshold — Minimum temperature, expressed in degrees, that will activate
an alarm.
Maximum Warning Threshold — Maximum temperature, expressed in degrees, that will activate
an alarm.
Minimum Failure Threshold — Minimum temperature, expressed in degrees, that will cause the
enclosure to fail.
Maximum Failure Threshold — Maximum temperature, expressed in degrees, that will cause the
enclosure to fail.
Units — Measurement type of temperature, such as Celsius.
Power Supplies
Status — Status of the power supplies.
Name — Name of the power supply, such as "Power Supply 1."
State — Current state of the power supply.