User's Manual
54 omreport: Viewing System Status Using the Instrumentation Service
omreport chassis volts
Use the omreport chassis volts command to view properties of your system’s voltage probes. When
you type:
omreport chassis volts index=
n
The index parameter is optional. If you do not specify the index, Server Administrator displays a
summary of status, readings, and thresholds set for any voltage probes that might be present on your
system. If you specify the index, Server Administrator displays a summary for a specific voltage probe.
omreport system Commands
Use the omreport system commands to view logs, to see how shutdown actions are configured, and to
view threshold values, cost of ownership information, and information about how recovery actions are
configured.
omreport system
Use the omreport system command to see a general status for your system components. When you
specify a level 3 command, such as omreport system shutdown, you can get detailed information for one
system component rather than the high level status that you get with omreport system. Type:
omreport system
If your system has both a main system chassis and at least one direct attached storage device, Server
Administrator may display a summary that resembles the following example.
NOTE: As with all output shown in this guide, the following output is an example and may vary depending on your
system configuration.
SEVERITY : COMPONENT
Ok : Main System Chassis
Critical : Storage