User's Manual
168 Using the Storage Management Service
omconfig Enable Enclosure Alarm
Use the following omconfig command syntax to enable the enclosure alarm:
Complete Syntax
omconfig storage enclosure action=enablealarm controller=id
enclosure=<ENCLOSUREID>
where id is the controller ID. The <ENCLOSUREID> variable specifies the enclosure.
Example for SCSI, SATA, and ATA Controllers:
For example, to enable the alarm on the enclosure attached to connector 2 on controller 1, enter:
omconfig storage enclosure action=enablealarm controller=1
enclosure=2
Example for SAS Controllers:
For example, to enable the alarm on enclosure 3 attached to connector 2 on controller 1, enter:
omconfig storage enclosure action=enablealarm controller=1
enclosure=2:3
action=setassetname controller=id enclosure=<ENCLOSUREID>
assetname=<string>
action=settempprobes controller=id enclosure=<ENCLOSUREID>
index=id minwarn=n maxwarn=n
action=resettempprobes controller=id enclosure=
<ENCLOSUREID> index=id
action=setalltempprobes controller=id
enclosure=<ENCLOSUREID> minwarn=n
maxwarn=n
action=resetalltempprobes controller=id
enclosure=<ENCLOSUREID>
action=blink controller=id
enclosure=<ENCLOSUREID>
Table 8-26. omconfig Enclosure Commands (continued)
Required Command Levels (1, 2, 3) Optional name=value pairs