User's Manual

160 Using the Storage Management Service
omconfig Online Array Disk
Use the following omconfig command syntax to bring an offline array disk back online.
Complete Syntax
omconfig storage adisk action=online controller=id adisk=<ADISKID>
where id is the controller ID. The <ADISK> variable specifies the array disk.
To obtain these values, you would enter omreport storage controller to display the controller IDs and
then enter omreport storage adisk controller=ID to display the IDs for the array disks attached to the
controller.
Example Syntax
In this example, you want to bring array disk 3 on connector 0 of controller 1 back online. On a SAS
controller, the array disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers:
To online the array disk described in this example, enter:
omconfig storage adisk action=online controller=1 adisk=0:3
Example for SAS Controllers:
To online the array disk described in this example, enter:
omconfig storage adisk action=online controller=1 adisk=0:2:3
omconfig Assign Global Hot Spare
Use the following omconfig command syntax to assign an array disk as a global hot spare.
Complete Syntax
omconfig storage adisk action=assignglobalhotspare controller=id
adisk=<ADISKID> assign=yes
where id is the controller ID. The <ADISK> variable specifies the array disk.
To obtain these values, enter omreport storage controller to display the controller IDs and then enter
omreport storage adisk controller=ID to display the IDs for the array disks attached to the controller.
Example Syntax
In this example, you want to assign array disk 3 on connector 0 of controller 1 as a global hot spare. On a
SAS controller, the array disk resides in enclosure 2.