User's Manual

Using the Storage Management Service 135
omconfig Rescan Controller
Use the following omconfig command syntax to rescan a controller. See the online help for more
information about using this command.
Complete Syntax
omconfig storage controller action=rescan controller=id
where id is the controller ID as reported by the omreport storage controller command.
Example Syntax
For example, to rescan controller 1, enter:
omconfig storage controller action=rescan controller=1
NOTE: The rescan controller is not supported on non–RAID SCSI controllers. You must reboot the system before
Storage Management can see configuration changes on non-RAID SCSI controllers.
omconfig Global Rescan Controller
The omconfig storage controller action=globalrescan command was supported in previous releases of
Storage Management. This command has been replaced by the omconfig storage globalinfo action=
globalrescan command. When rescanning all controllers on the system and creating CLI scripts, it is
preferable to use the omconfig storage globalinfo action=globalrescan command.
See the online help for more information about using this command.
omconfig Enable Controller Alarm
Use the following omconfig command syntax to enable the controller alarm. See the online help for
more information about using this command.
Complete Syntax
omconfig storage controller action=enablealarm controller=id
where id is the controller ID as reported by the omreport storage controller command.
action=setpatrolreadmode controller=id
mode=manual | auto | disable
action=startpatrolread controller=id
action=stoppatrolread controller=id
Table 8-16. omconfig Controller Commands (continued)
Required Command Levels (1, 2, 3) Optional name=value pairs