User's Manual
Using the Storage Management Service 129
omreport Temperature Probe Status
omreport Fan Status
Table 8-9. omreport Temperature Probe Commands
Required Command Levels (1, 2, 3)
and name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information
for all enclosures attached to
the system.
controller=id enclosure=id
info=temps
where id is the controller number
and the enclosure number. For
example: controller=0 enclosure=2
Displays the temperature probes
for the specified enclosure.
controller=id enclosure=id
info=temps index=n
where id is the controller number
and the enclosure number and “n” is
the number of a temperature probe.
For example: controller=0
enclosure=2 info=temps index=1
Displays the specified
temperature probe.
Table 8-10. omreport Fan Status
Required Command Levels (1, 2, 3)
and name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for
all enclosures attached to the system.
controller=id enclosure=id
info=fans
where id is the controller number
and the enclosure number.
For example: controller=0
enclosure=2
Displays the fans for the specified
enclosure.
controller=id enclosure=id
info=fan index=n
where id is the controller number
and the enclosure number and “n”
is the number of a fan.
For example: controller=0
enclosure=2 info=fans index=1
Displays the specified fan.