Messages Reference Guide

Storage Management Message Reference 97
2357 SAS expander error:
%1
NOTE: %1 is a
substitution variable
that will appear in the
alert description for
specific details about
the alert.
Critical /
Failure /
Error
Cause: The text for this alert is generated by
the firmware and can vary depending on the
situation.
Action: There may be a problem with the
enclosure. Check the health of the enclosure
and its components. by selecting the
enclosure object in the tree view. The Health
subtab displays a red X or yellow exclamation
point for enclosure components that are
failed or degraded. See the enclosure
documentation for more information.
754 None
2358 The battery charge
cycle is complete.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None.
1151 None
2359 The physical disk is
not certified.
Warning /
Non-critical
Cause: The physical disk does not comply
with the standards set by Dell and is not
supported.
Action: Replace the physical disk with a
physical disk that is supported.
903 None
2360 A user has discarded
data from the
controller cache.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None.
751 None
2361 Array disk(s) that are
part of a virtual disk
have been removed
while the system was
shut down. This
removal was
discovered during
system start-up.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None.
751 None
2362 Array disk(s) have
been removed from a
virtual disk. The
virtual disk will be in
Failed state during
the next system
reboot.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None.
751 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number