Storage Management Message Reference 95
2349 A bad disk block
could not be
reassigned during a
write operation.
Critical /
Failure /
Error
Cause: A write operation could not complete
because the disk contains bad disk blocks
that could not be reassigned. Data loss may
have occurred and data redundancy may also
be lost.
Action: Replace the disk.
904 None
2350 There was an
unrecoverable disk
media error during
the rebuild.
Critical /
Failure /
Error
Cause: The rebuild encountered an
unrecoverable disk media error.
Action: Replace the disk.
904 None
2351 A physical disk is
marked as missing.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None.
901 None
2352 A physical disk that
was marked as
missing has been
replaced.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None.
901 None
2353 The enclosure
temperature has
returned to normal.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None.
851 None
2354 Enclosure firmware
download in progress.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None.
851 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number