94 Storage Management Message Reference
2343 The "Check
Consistency" logging
of inconsistent parity
data is disabled.
Warning /
Non-critical
Cause: The "Check Consistency" operation
can no longer report errors in the parity data.
Action: See the hardware documentation for
more information.
1203 None
2344 The virtual disk
initialization
terminated.
Warning /
Non-critical
Cause: A user has cancelled the virtual disk
initialization.
Action: Restart the initialization.
1203 None
2345 The virtual disk
initialization failed.
Critical /
Failure /
Error
Cause: The controller cannot communicate
with the attached devices. A disk may be
removed or contain errors. The cables may
also be loose or defective.
Action: Check the health of attached devices.
Review the Alert Log for significant events
and make sure the cables are attached
securely.
1204 None
2346 Error occurred: %1
NOTE: %1 is a
substitution variable
that will appear in the
alert description for
specific details about
the alert.
Warning /
Non-critical
Cause: The text for this alert is generated by
the firmware and can vary depending on
the situation.
Action: Check the health of attached devices.
Review the Alert Log for significant events.
You may need to replace faulty hardware.
Make sure the cables are attached securely.
See the hardware documentation for
more information.
903 None
2347 The rebuild failed due
to errors on the
source physical disk.
Critical /
Failure /
Error
Cause: You are attempting to rebuild data
that resides on a defective disk.
Action: Replace the source disk and restore
from backup.
904 None
2348 The rebuild failed due
to errors on the target
physical disk.
Critical /
Failure /
Error
Cause: You are attempting to rebuild data on
a disk that is defective.
Action: Replace the target disk. If a rebuild
does not automatically start after replacing
the disk, initiate the "Rebuild" task. You may
need to assign the new disk as a hot spare to
initiate the rebuild.
904 None
Table 4-1. Storage Management Messages (continued)