Messages Reference Guide

90 Storage Management Message Reference
2324 The AC power supply
cable has been
removed.
Critical /
Failure /
Error
Cause: The power cable may be pulled out or
removed. The power cable may also have
overheated and become warped and
nonfunctional.
Action: Replace the power cable.
1004 None
2325 The power supply
cable has been
inserted.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
1001 None
2326 A foreign
configuration has
been detected.
Ok /
Normal
Cause: This alert is provided for
informational purposes. The controller has
array disks that were moved from another
controller. These array disks contain virtual
disks that were created on the other
controller. See Import Foreign Configuration
and Clear Foreign Configuration for
more information.
Action: None
751 None
2327 The NVRAM has
corrupted data. The
controller is
reinitializing the
NVRAM.
Warning /
Non-critical
Cause: The NVRAM has corrupted data. This
may ocurr after a power surge, a battery
failure, or for other reasons. The controller is
reinitializing the NVRAM.
Action: None. The controller is taking the
required corrective action. If this alert is
generated often (such as during each reboot),
replace the controller.
753 None
2328 The NVRAM has
corrupt data.
Warning /
Non-critical
Cause: The NVRAM has corrupt data. The
controller is unable to correct the situation.
Action: Replace the controller.
753 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number