Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
- Event Message Reference
- Miscellaneous Messages
- Temperature Sensor Messages
- Cooling Device Messages
- Voltage Sensor Messages
- Current Sensor Messages
- Chassis Intrusion Messages
- Redundancy Unit Messages
- Power Supply Messages
- Memory Device Messages
- Fan Enclosure Messages
- AC Power Cord Messages
- Hardware Log Sensor Messages
- Processor Sensor Messages
- Pluggable Device Messages
- System Event Log Messages for IPMI Systems
- Storage Management Message Reference
- Index
- Messages Reference Guide

Storage Management Message Reference 87
2309 An array disk is
incompatible.
Warning /
Non-critical
Cause: You have attempted to replace a disk
with another disk that is using an
incompatible technology. For example, you
may have replaced one side of a mirror with a
SAS disk when the other side of the mirror is
using SATA technology.
Action: See the hardware documentation for
information on replacing disks.
903 None
2310 A virtual disk is
permanently
degraded.
Critical /
Failure /
Error
Cause: A redundant virtual disk has lost
redundancy. This may occur when the virtual
disk suffers the failure of multiple array disks.
In this case, both the source array disk and
the target disk with redundant data have
failed. A rebuild is not possible because there
is no longer redundancy.
Action: Replace the failed disks and restore
from backup.
1204 None
2311 The firmware on the
EMMs is not the
same version. EMM0
%1 EMM1 %2
NOTE: %1 and %2 are
substitution variables
that will appear in the
alert description for
specific details about
the alert.
Warning /
Non-critical
Cause: The firmware on the EMM modules is
not the same version. It is required that both
modules have the same version of the
firmware. This alert may be caused if you
attempt to insert an EMM module that has a
different firmware version than an
existing module.
Action: Upgrade to the same version of the
firmware on both EMM modules.
853 None
2312 A power supply in the
enclosure has an
AC failure.
Warning /
Non-critical
Cause: The power supply has an AC failure.
Action: Replace the power supply.
1003 None
2313 A power supply in the
enclosure has a
DC failure.
Warning /
Non-critical
Cause: The power supply has a DC failure.
Action: Replace the power supply.
1003 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number