Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
- Event Message Reference
- Miscellaneous Messages
- Temperature Sensor Messages
- Cooling Device Messages
- Voltage Sensor Messages
- Current Sensor Messages
- Chassis Intrusion Messages
- Redundancy Unit Messages
- Power Supply Messages
- Memory Device Messages
- Fan Enclosure Messages
- AC Power Cord Messages
- Hardware Log Sensor Messages
- Processor Sensor Messages
- Pluggable Device Messages
- System Event Log Messages for IPMI Systems
- Storage Management Message Reference
- Index
- Messages Reference Guide

Storage Management Message Reference 85
2299 Bad PHY %1
NOTE: %1 is a
substitution variable
that will appear in the
alert description for
specific details about
the alert.
Critical /
Failure /
Error
Cause: There is a problem with a physical
connection or PHY.
Action: Replace the EMM that contains the
bad PHY. See the hardware documentation
for information on replacing the EMM.
Attach the storage to a different connector, if
available. Make sure the cables are attached
securely.
854 None
2300 The enclosure is
unstable.
Critical /
Failure /
Error
Cause: The controller is not receiving a
consistent response from the enclosure.
There could be a firmware problem or an
invalid cabling configuration. If the cables are
too long, they will degrade the signal.
Action: Power down all enclosures attached
to the system and reboot the system. If the
problem persists, upgrade the firmware to the
latest supported version. You can download
the most current version of the driver and
firmware from support.dell.com. Make sure
the cable configuration is valid. See the
hardware documentation for valid cabling
configurations.
854 None
2301 The enclosure has a
hardware error.
Critical /
Failure /
Error
Cause: The enclosure or an enclosure
component is in a Failed or Degraded state.
Action: Check the health of the enclosure
and its components. Replace any hardware
that is in a Failed state. See the hardware
documentation for more information.
854 None
2302 The enclosure is not
responding.
Critical /
Failure /
Error
Cause: The enclosure or an enclosure
component is in a Failed or Degraded state.
Action: Check the health of the enclosure
and its components. Replace any hardware
that is in a Failed state. See the hardware
documentation for more information.
854 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number