84 Storage Management Message Reference
2293 The EMM has failed. Critical /
Failure /
Error
Cause: The failure may be caused by a loss of
power to the EMM. The EMM self test may
also have identified a failure. There could also
be a firmware problem or a multi-bit error.
Action: Replace the EMM. See the hardware
documentation for information on replacing
the EMM.
854 None
2294 A device has been
inserted.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
752, 802,
852, 902,
952, 1002,
1052,
1102,
1152, 1202
None
2295 A device has been
removed.
Critical /
Failure /
Error
Cause: A device has been removed and the
system is no longer functioning in
optimal condition.
Action: Replace the device.
754, 804,
854, 904,
954, 1004,
1054,
1104,
1154, 1204
None
2296 An EMM has been
inserted.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
851 None
2297 An EMM has been
removed.
Critical /
Failure /
Error
Cause: An EMM has been removed.
Action: Replace the EMM. See the hardware
documentation for information on replacing
the EMM.
854 None
2298 There is a bad sensor
on an enclosure.
Warning /
Non-critical
Cause: The enclosure has a bad sensor. The
enclosure sensors monitor the fan speeds,
temperature probes, etc.
Action: See the hardware documentation for
more information.
853 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event