Messages Reference Guide

Storage Management Message Reference 81
2277 The global hot spare
is too small.
Warning /
Non-critical
Cause: The global hot spare is not large
enough to protect all virtual disks that reside
on the controller.
Action: Assign a larger disk as the global
hot spare.
903 None
2278 The controller battery
charge level is below a
normal threshold.
Critical /
Failure /
Error
Cause: The battery is discharging. A battery
discharge is a normal activity during the
battery Learn cycle. Before completing, the
battery Learn cycle recharges the battery.
You should receive alert 2179 when the
recharge occurs.
Action: Check if the battery Learn cycle is in
progress. Alert 2176 indicates that the battery
Learn cycle has initiated. The battery also
displays the Learn state while the Learn cycle
is in progress. If a Learn cycle is not in
progress, replace the battery pack.
1154 None
2279 The controller battery
charge level is above a
normal threshold.
Ok /
Normal
Cause: This alert is provided for
informational purposes. This alert indicates
that the battery is recharging during the
battery Learn cycle.
Action: None
1151 None
2280 A disk media error has
been corrected.
Ok /
Normal
Cause: A disk media error was detected while
the controller was completing a background
task. A bad disk block was identified. The
disk block has been remapped.
Action: Consider replacing the disk. If you
receive this alert frequently, be sure to replace
the disk. You should also routinely back up
your data.
1201 None
2281 Virtual disk has
inconsistent data.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
1201 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array