80 Storage Management Message Reference
2270 The array disk "Clear"
operation failed.
Critical /
Failure /
Error
Cause: A "Clear" operation was being
performed on an array disk, but it was
interrupted and did not complete
successfully. The controller may have lost
communication with the disk. The disk may
have been removed or the cables may be
loose or defective.
Action: Check if the disk is in and not in a
failed state. Make sure the cables are attached
securely.
Restart the "Clear" operation.
904 None
2271 The "Patrol Read"
corrected a media
error.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
901 None
2272 "Patrol Read" found
an uncorrectable
media error.
Critical /
Failure /
Error
Cause: The "Patrol Read" task has faced an
error that cannot be corrected. There may be
a bad disk block that cannot be remapped.
Action: Replace the array disk to avoid future
data loss.
903 None
2273 Bad media. Critical /
Failure /
Error
Cause: A source (array) disk in a redundant
virtual disk has a bad disk block. The
algorithm that maintains redundant data has
created a similar bad block on the target
redundant disk to maintain consistency in
disk block addressing. Data has been lost.
Action: Restore from backup.
904 None
2274 The array disk rebuild
has resumed.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
901 None
2276 The dedicated hot
spare is too small.
Warning /
Non-critical
Cause: The dedicated hot spare is not large
enough to protect all virtual disks that reside
on the disk group.
Action: Assign a larger disk as the dedicated
hot spare.
903 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number