Messages Reference Guide

Storage Management Message Reference 79
2266 Controller log file
entry: %1
%1 is a substitution
variable that will
appear in the alert
description for
specific details about
the alert.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
751 None
2267 The controller
reconstruct rate has
changed.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
751 None
2268 %1, Storage
Management has lost
communication with
this RAID controller
and attached storage.
An immediate reboot
is strongly
recommended to
avoid further
problems. If the
reboot does not
restore
communication,
there may be a
hardware failure.
NOTE: %1 is a
substitution variable
that will appear in the
alert description for
specific details about
the alert.
Critical /
Failure /
Error
Cause: Storage Management has lost
communication with a device. There may be
faulty hardware or loose or defective cables.
Action: Reboot the system. If the problem is
not resolved, check for hardware failures. Any
failed component must be replaced. Make
sure the cables are attached securely.
See the hardware documentation for more
diagnostics information.
104 None
2269 The array disk "Clear"
operation has
completed.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
901 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number