Messages Reference Guide

78 Storage Management Message Reference
2260 An enclosure blink
has ceased.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
851 None
2261 A global rescan has
initiated.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
101 None
2262 Smart thermal
shutdown is enabled.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
101 None
2263 Smart thermal
shutdown is disabled.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
101 None
2264 A device is missing. Warning /
Non-critical
Cause: The controller cannot communicate
with a device. The device may be removed.
There may also be a bad or loose cable.
Action: Check if the device is in and
connected. If it is in, check the cables.
Also check the connection to the controller
battery and the battery health. A battery with
a weak or depleted charge may cause this alert.
753, 803,
853, 903,
953, 1003,
1053,
1103,
1153, 1203
None
2265 A device is in an
unknown state.
Warning /
Non-critical
Cause: The controller cannot communicate
with a device. The state of the device cannot
be determined. There may be a bad or loose
cable. The system may also be experiencing
problems with the application programming
interface (API). There could also be a
problem with the driver or firmware.
Action: Check the cables.
Check if the controller has a supported
version of the driver and firmware. You can
download the most current version of the
driver and firmware from support.dell.com.
Rebooting the system may also resolve this
problem.
753, 803,
853, 903,
953, 1003,
1053,
1103,
1153, 1203
None