Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
- Event Message Reference
- Miscellaneous Messages
- Temperature Sensor Messages
- Cooling Device Messages
- Voltage Sensor Messages
- Current Sensor Messages
- Chassis Intrusion Messages
- Redundancy Unit Messages
- Power Supply Messages
- Memory Device Messages
- Fan Enclosure Messages
- AC Power Cord Messages
- Hardware Log Sensor Messages
- Processor Sensor Messages
- Pluggable Device Messages
- System Event Log Messages for IPMI Systems
- Storage Management Message Reference
- Index
- Messages Reference Guide

Storage Management Message Reference 69
2171 The controller battery
temperature is above
normal.
Warning /
Non-critical
Cause: The battery may be recharging, the
room temperature may be too hot, or the fan
in the system may be degraded or failed.
Action: If this alert was generated due to a
battery recharge, the situation will correct
when the recharge is complete. You should
also check if the room temperature is normal
and that the system components are
functioning properly.
1153 None
2172 The controller battery
temperature is
normal.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
1151 None
2174 The controller battey
has been removed.
Warning /
Non-critical
Cause: The controller cannot communicate
with the battery, the battery may be removed,
or the contact point between the controller
and the battery may be burnt or corroded.
Action: Replace the battery if it is not in. If
the contact point between the battery and the
controller is burnt or corroded, you will need
to replace either the battery or the controller,
or both. See the hardware documentation for
information on how to safely access, remove,
and replace the battery.
1153 None
2175 The controller battery
has been replaced.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
1151 None
2176 The controller battery
Learn cycle has
started.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
1151 None
2177 The controller battery
Learn cycle has
completed.
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
1151 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number