Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
- Event Message Reference
- Miscellaneous Messages
- Temperature Sensor Messages
- Cooling Device Messages
- Voltage Sensor Messages
- Current Sensor Messages
- Chassis Intrusion Messages
- Redundancy Unit Messages
- Power Supply Messages
- Memory Device Messages
- Fan Enclosure Messages
- AC Power Cord Messages
- Hardware Log Sensor Messages
- Processor Sensor Messages
- Pluggable Device Messages
- System Event Log Messages for IPMI Systems
- Storage Management Message Reference
- Index
- Messages Reference Guide

62 Storage Management Message Reference
2132 Driver version
mismatch
Warning /
Non-critical
Cause: The controller driver is not a
supported version.
Action: Install a supported version of the
driver. If you do not have a supported driver
version available, it can be downloaded from
the Dell support site at support.dell.com.
If you do not have a supported version of the
driver available, check with your support
provider for information on how to obtain the
most current driver.
753 None
2135 Array Manager is
installed on the
system
Warning /
Non-critical
Cause: Storage Management has been
installed on a system that has an Array
Manager installation.
Action: Installing Storage Management and
Array Manager on the same system is not a
supported configuration. Uninstall either
Storage Management or Array Manager.
103 None
2136 Virtual disk
initialization
Ok /
Normal
Cause: Virtual disk initialization is in
progress. This alert is provided for
informational purposes.
Action: None
1201 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number