Messages Reference Guide

Storage Management Message Reference 59
2121 Device returned to
normal
Ok /
Normal
Cause: A device that was previously in an
error state has returned to a normal state.
For example, if an enclosure became too hot
and subsequently cooled down, then you may
receive this alert.
Action: This alert is provided for
informational purposes.
752, 802,
852, 902,
952, 1002,
1052,
1102,
1152, 1202
None
2122 Redundancy
degraded
Warning /
Non-critical
Cause: One or more of the enclosure
components has failed. For example, a fan or
power supply may have failed. Although the
enclosure is currently operational, the failure
of additional components could cause the
enclosure to fail.
Action: Identify and replace the failed
component. To identify the failed
component, select the enclosure in the tree
view and click the Health subtab. Any failed
component will be identified with a red X on
the enclosure’s Health subtab. Alternatively,
you can select the Storage object and click
the Health subtab. The controller status
displayed on the Health subtab indicates
whether a controller has a failed or degraded
component. See the enclosure
documentation for information on replacing
enclosure components and for other
diagnostic information.
1305 None
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number