Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
- Event Message Reference
- Miscellaneous Messages
- Temperature Sensor Messages
- Cooling Device Messages
- Voltage Sensor Messages
- Current Sensor Messages
- Chassis Intrusion Messages
- Redundancy Unit Messages
- Power Supply Messages
- Memory Device Messages
- Fan Enclosure Messages
- AC Power Cord Messages
- Hardware Log Sensor Messages
- Processor Sensor Messages
- Pluggable Device Messages
- System Event Log Messages for IPMI Systems
- Storage Management Message Reference
- Index
- Messages Reference Guide

Storage Management Message Reference 55
2104 Controller battery is
reconditioning
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
1151 581
2105 Controller battery
recondition is
completed
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
1151 582
2106 Smart FPT exceeded Warning /
Non-critical
Cause: A disk on the specified controller has
received a SMART alert (predictive failure)
indicating that the disk is likely to fail in the
near future.
Action: Replace the disk that has received the
SMART alert. If the array disk is a member of
a non-redundant virtual disk, then back up the
data before replacing the disk. Removing an
array disk that is included in a non-redundant
virtual disk will cause the virtual disk to fail
and may cause data loss.
903 585
2107 Smart configuration
change
Critical /
Failure /
Error
Cause: A disk has received a SMART alert
(predictive failure) after a configuration change.
The disk is likely to fail in the near future.
Action: Replace the disk that has received the
SMART alert. If the array disk is a member of
a non-redundant virtual disk, then back up
the data before replacing the disk. Removing
an array disk that is included in a non-
redundant virtual disk will cause the virtual
disk to fail and may cause data loss.
904 586
2108 Smart warning Warning /
Non-critical
Cause: A disk has received a SMART alert
(predictive failure). The disk is likely to fail in
the near future.
Action: Replace the disk that has received the
SMART alert. If the array disk is a member of
a non-redundant virtual disk, then back up
the data before replacing the disk. Removing
an array disk that is included in a non-
redundant virtual disk will cause the virtual
disk to fail and may cause data loss.
903 587
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number