Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
- Event Message Reference
- Miscellaneous Messages
- Temperature Sensor Messages
- Cooling Device Messages
- Voltage Sensor Messages
- Current Sensor Messages
- Chassis Intrusion Messages
- Redundancy Unit Messages
- Power Supply Messages
- Memory Device Messages
- Fan Enclosure Messages
- AC Power Cord Messages
- Hardware Log Sensor Messages
- Processor Sensor Messages
- Pluggable Device Messages
- System Event Log Messages for IPMI Systems
- Storage Management Message Reference
- Index
- Messages Reference Guide

54 Storage Management Message Reference
2100 Temperature
exceeded the
maximum warning
threshold
Warning /
Non-critical
Cause: The array disk enclosure is too hot.
A variety of factors can cause the excessive
temperature. For example, a fan may have
failed, the thermostat may be set too high, or
the room temperature may be too hot.
Action: Check for factors that may cause
overheating. For example, verify that the
enclosure fan is working. You should also
check the thermostat settings and examine
whether the enclosure is located near a heat
source. Make sure the enclosure has enough
ventilation and that the room temperature is
not too hot. See the enclosure
documentation for more
diagnostic information.
1053 591
2101 Temperature dropped
below the minimum
warning threshold
Warning /
Non-critical
Cause: The array disk enclosure is too cool.
Action: Check whether the thermostat
setting is too low and whether the room
temperature is too cool.
1053 592
2102 Temperature
exceeded the
maximum failure
threshold
Critical /
Failure /
Error
Cause: The array disk enclosure is too hot.
A variety of factors can cause the excessive
temperature. For example, a fan may have
failed, the thermostat may be set too high, or
the room temperature may be too hot.
Action: Check for factors that may cause
overheating. For example, verify that the
enclosure fan is working. You should also
check the thermostat settings and examine
whether the enclosure is located near a heat
source. Make sure the enclosure has enough
ventilation and that the room temperature is
not too hot. See the enclosure documentation
for more diagnostic information.
1054 593
2103 Temperature dropped
below the minimum
failure threshold
Critical /
Failure /
Error
Cause: The array disk enclosure is too cool.
Action: Check whether the thermostat
setting is too low and whether the room
temperature is too cool.
1054 594
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number