Messages Reference Guide

Storage Management Message Reference 47
2050 Array disk offline Warning /
Non-critical
Cause: A physical disk in the array is offline.
A disk can be made offline during a "Prepare
to Remove" operation or because a user
manually put the disk offline.
Action:
Perform a rescan. You can also select
the offline disk and perform a Make
Online operation.
903 502
2051 Array disk degraded Warning /
Non-critical
Cause: An array disk has reported an error
condition and may be degraded. The array
disk may have reported the error condition in
response to a consistency check or
other operation.
Action: Replace the degraded array disk.
You can identify which disk is degraded by
locating the disk that has a red "X" for its
status. Perform a rescan after replacing
the disk.
903 503
2052 Array disk inserted Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
901 504
2053 Virtual disk created Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
1201 505
2054 Virtual disk deleted Warning /
Non-critical
Cause: A virtual disk has been deleted.
"Performing a Reset Configuration" operation
may detect that a virtual disk has been
deleted and generate this alert.
Action: None
1203 506
2055 Virtual disk
configuration
changed
Ok /
Normal
Cause: This alert is provided for
informational purposes.
Action: None
1201 507
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number