Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
- Event Message Reference
- Miscellaneous Messages
- Temperature Sensor Messages
- Cooling Device Messages
- Voltage Sensor Messages
- Current Sensor Messages
- Chassis Intrusion Messages
- Redundancy Unit Messages
- Power Supply Messages
- Memory Device Messages
- Fan Enclosure Messages
- AC Power Cord Messages
- Hardware Log Sensor Messages
- Processor Sensor Messages
- Pluggable Device Messages
- System Event Log Messages for IPMI Systems
- Storage Management Message Reference
- Index
- Messages Reference Guide

System Event Log Messages for IPMI Systems 37
System Event Log Messages for IPMI Systems
The following tables list the system event log (SEL) messages, their severity, and cause.
NOTE: For corrective actions, see the appropriate documentation.
Temperature Sensor Events
The temperature sensor event messages help protect critical components by alerting the systems
management console when the temperature rises inside the chassis. These event messages use
additional variables, such as sensor location, chassis location, previous state, and temperature sensor
value or state.
Table 3-1. Temperature Sensor Events
Event Message Severity Cause
<
Sensor Name/Location
>
temperature sensor detected a
failure <
Reading
> where <
Sensor
Name/Location
> is the entity
that this sensor is monitoring.
For example, "PROC Temp" or
"Planar Temp."
Reading is specified in degree
Celsius. For example 100 C.
Critical Temperature of the backplane board,
system board, or the carrier in the specified
system <Sensor Name/Location> exceeded
the critical threshold.
<Sensor Name/Location
>
temperature sensor detected a
warning <
Reading
>.
Warning Temperature of the backplane board,
system board, or the carrier in the specified
system <Sensor Name/Location> exceeded
the non-critical threshold.
<
Sensor Name/Location
>
temperature sensor returned to
warning state <
Reading
>.
Warning Temperature of the backplane board,
system board, or the carrier in the specified
system <Sensor Name/Location> returned
from critical state to non-critical state.
<
Sensor Name/Location
>
temperature sensor returned to
normal state <
Reading
>.
Information Temperature of the backplane board,
system board, or the carrier in the specified
system <Sensor Name/Location> returned
to normal operating range.