Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
- Event Message Reference
- Miscellaneous Messages
- Temperature Sensor Messages
- Cooling Device Messages
- Voltage Sensor Messages
- Current Sensor Messages
- Chassis Intrusion Messages
- Redundancy Unit Messages
- Power Supply Messages
- Memory Device Messages
- Fan Enclosure Messages
- AC Power Cord Messages
- Hardware Log Sensor Messages
- Processor Sensor Messages
- Pluggable Device Messages
- System Event Log Messages for IPMI Systems
- Storage Management Message Reference
- Index
- Messages Reference Guide

Event Message Reference 33
Hardware Log Sensor Messages
Hardware logs provide hardware status messages to systems management software. On certain systems,
the hardware log is implemented as a circular queue. When the log becomes full, the oldest status
messages are overwritten when new status messages are logged. On some systems, the log is not circular.
On these systems, when the log becomes full, subsequent hardware status messages are lost. Hardware
log sensor messages listed in
Ta ble 2-12 provide status and warning information about the noncircular
logs that may fill up, resulting in lost status messages.
1503 AC power has been lost
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Warning An AC power cord has lost its
power, but there is sufficient
redundancy to classify this as a
warning. The sensor location and
chassis location information
are provided.
1504 AC power has been lost
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Error An AC power cord has lost its
power, and lack of redundancy
requires this to be classified as an
error. The sensor location and
chassis location information
are provided.
1505 AC power has been lost
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Error An AC power cord sensor in the
specified system failed. The AC
power cord status cannot be
monitored. The sensor location
and chassis location information
are provided.
Table 2-12. Hardware Log Sensor Messages
Event ID Description Severity Cause
1550 Log monitoring has been disabled
Log type:
<Log type>
Information A hardware log sensor in the
specified system is disabled. The
log type information is provided.
1551 Log status is unknown
Log type:
<Log type>
Information A hardware log sensor in the
specified system could not obtain a
reading. The log type information
is provided.
Table 2-11. AC Power Cord Messages (continued)
Event ID Description Severity Cause