Messages Reference Guide

30 Event Message Reference
Memory Device Messages
Memory device messages listed in Table 2-9 provide status and warning information for memory
modules present in a particular system. Memory devices determine health status by monitoring the
ECC
memory correction rate and the type of memory events that have occurred.
NOTE: A critical status does not always indicate a system failure or loss of data. In some instances, the system has
exceeded the ECC correction rate. Although the system continues to function, you should perform system
maintenance as described in Table
2-9.
NOTE: In Table 2-9, <status> can be either critical or non-critical.
1354 Power supply detected a failure
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Previous state was:
<State>
Power Supply type:
<type of power
supply>
<Additional power supply status
information>
If in configuration error state:
Configuration error type:
<type of
configuration error>
Error A power supply has been
disconnected or has failed. The
sensor location, chassis location,
previous state, and additional
power supply status information
are provided.
1355 Power supply sensor detected a non-
recoverable value
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Previous state was:
<State>
Power Supply type:
<type of power
supply>
<Additional power supply status
information>
If in configuration error state:
Configuration error type:
<type of
configuration error>
Error A power supply sensor in the
specified system detected an
error from which it cannot
recover. The sensor location,
chassis location, previous state,
and additional power supply
status information are provided.
Table 2-8. Power Supply Messages (continued)
Event ID Description Severity Cause