Messages Reference Guide
Table Of Contents
- Dell OpenManage™ Server Administrator
- Messages Reference Guide
- Introduction
- Event Message Reference
- Miscellaneous Messages
- Temperature Sensor Messages
- Cooling Device Messages
- Voltage Sensor Messages
- Current Sensor Messages
- Chassis Intrusion Messages
- Redundancy Unit Messages
- Power Supply Messages
- Memory Device Messages
- Fan Enclosure Messages
- AC Power Cord Messages
- Hardware Log Sensor Messages
- Processor Sensor Messages
- Pluggable Device Messages
- System Event Log Messages for IPMI Systems
- Storage Management Message Reference
- Index
- Messages Reference Guide

Event Message Reference 19
Cooling Device Messages
Cooling device sensors listed in Table 2-3 monitor how well a fan is functioning. Cooling device messages
provide status and warning information for fans in a particular chassis.
Table 2-3. Cooling Device Messages
Event ID Description Severity Cause
1100 Fan sensor has failed
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Previous state was:
<State>
Fan sensor value:
<Reading>
Information A fan sensor in the specified
system is not functioning. The
sensor location, chassis location,
previous state, and fan sensor
value are provided.
1101 Fan sensor value unknown
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Previous state was:
<State>
Fan sensor value:
<Reading>
Information A fan sensor in the specified
system could not obtain a
reading. The sensor location,
chassis location, previous state,
and a nominal fan sensor value
are provided.
1102 Fan sensor returned to a normal value
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Previous state was:
<State>
Fan sensor value:
<Reading>
Information A fan sensor reading on the
specified system returned to a
valid range after crossing a
warning threshold. The sensor
location, chassis location,
previous state, and fan sensor
value are provided.
1103 Fan sensor detected a warning value
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Previous state was:
<State>
Fan sensor value:
<Reading>
Warning A fan sensor reading in the
specified system exceeded a
warning threshold. The sensor
location, chassis location,
previous state, and fan sensor
value are provided.
1104 Fan sensor detected a failure value
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Previous state was:
<State>
Fan sensor value:
<Reading>
Error A fan sensor in the specified
system detected the failure of
one or more fans. The sensor
location, chassis location,
previous state, and fan sensor
value are provided.