Users Guide

Table Of Contents
4. In Set Threshold for PCIe SSD (1-99), enter the appropriate threshold value.
NOTE: If available spare threshold value is set an alert message is generated.
NOTE: The threshold value cannot be set to 100%.
5. Click Apply Changes.
NOTE: If you click Apply Changes without entering a new threshold value for either of the available options an error
message is displayed. Enter a new threshold value and then click Apply Changes to successfully complete the task.
6. After you click Apply Changes, Storage Management updates the system with the new threshold values. After the task is
completed, you will be redirected to the Information/Configuration window.
NOTE: The newly entered threshold values are retained even after you upgrade Server Administrator.
NOTE: When the Available Spare of the SSD drops below the configured threshold, an alert is logged and based on the
alert type selection the SNMP trap is received for the same. For more information on SNMP traps, see the Dell EMC
OpenManage SNMP Reference Guide at dell.com/openmanagemanuals. The threshold polling interval is scheduled to
repeat every five minutes.
Storage Controller Properties
The information displayed for each controller can vary depending on the controller characteristics.
NOTE:
The firmware and drivers listed in the Server Administrator Release Notes, see the minimum supported version for
these controllers. Later versions of the firmware and drivers are also supported. For the most recent driver and firmware
requirements, contact your service provider.
Table 10. Controller Properties
Property Definition
Status Displays the status of the controller.
ID Displays the controller ID as reported by the omreport CLI
command.
Name Displays the name of the controller. For more detailed
information on a controller, click its name on the controller
name.
Slot ID Displays the slot to which the controller is attached. Storage
Management displays Slot Not Applicable for controllers for
which it is unable to display the slot ID and Embedded for
embedded controllers.
NOTE: If Slot Not Available is displayed, you can identify
the slot ID by selecting the System > Main > System
Chassis > Slots object in the tree view and selecting the
Information tab. The Slot ID property on this tab may
display the correct information.
State Displays the state of the controller. Possible values are:
Ready The controller is functioning normally.
Degraded The controller has suffered a failure of a
component and is operating in a degraded state.
Failed The controller has suffered a failure of one or
more components and is no longer functioning.
Firmware Version Displays the version of the firmware available on the
controller.
46 Storage Information And Global Tasks